Keysight (Agilent) 5335A REPAIR and Keysight (Agilent) 5335A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 5335A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 5335A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 5335A   Description / Specification:    
Keysight (Agilent) 5335A Universal Counter

The HP 5335A is a Universal Counter that brought you more measurement power for your money than any other bench or systems universal counter available in the early 1980's. The power of HP's LSI counter-on-a-chip, first used in the 5315A/B Universal Counter, has been fully utilized in the 5335A to bring you high, 9 digit/second reciprocal frequency resolution to 200 MHz (1 GHz optional), 9 digit/second period resolution and 2 ns single shot time interval resolution. Manual/Automatic Triggering circuits allow you to either set the trigger levels yourself, or have the 5335A set them for you. Using this capability to the fullest carries the 5335A beyond the usual universal counter measurements of Frequency, Period, Time Interval, Ratio and Totalize to include measurements such as Pulse Width, Rise and Fall Time (10% to 90%), Slew Rate, Duty Cycle, Phase A Relative to B, and Inverse Time Interval (velocity). All done automatically at the push of a button. Also both A and B channel trigger levels and gate time may be measured and displayed on the standard 5335A. Math capabilities of Normalize, Offset, Scale, Last Display Deviation, and Measurement t-l Deviation are included as standard, as are atistical measurements of Mean (Average), Standard Deviation, and Smooth. These features carry the usefulness of the 5335A into the industrial, scientific and communications areas. For systems use, all measurement functions and many input controls of the 5335A are programmable via the Hewlett-Packard Interface Bus (HP-IB), which is included as standard. Options include an oven time base (Opt 010) for better measurement accuracy, a DC Voltmeter (Opt 020) to expand the measurement flexibility of the 5335A and a 1.3 GHz C Channel (Opt 030) to cover a wide variety of communications measurements.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 5335A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 5335A REPAIR and/or Keysight (Agilent) 5335A Universal Counter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: