Keysight (Agilent) 5348A CALIBRATION and Keysight (Agilent) 5348A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 5348A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 5348A   Description / Specification:    
Keysight (Agilent) 5348A 26.5 GHz Microwave Counter/Power Meter

The HP 5348A is a Microwave Counter/Power Meter that offers the convenience of a single instrument that meets both your frequency and power measurement needs. The HP 5348A counter/power meter makes these measurements to 26.5 GHz. It offers the accuracy and resolution that previously required a stand alone counter and a separate power meter. The HP 5348A is designed for ease of use; it has only 5 function keys. They are rugged, lightweight, and battery powered. The specifications for the 5348A is 500 MHz to 26.5 GHz, Sensitivity: 500 MHz to 12.4 GHz; -32 dBm / 12.4 GHz to 20 GHz -27 dBm / 20.0 GHz - 26.5 GHz: -20 dBm, Accuracy: ±LSD ±time base error x frequency(Input 1). Frequency range: 10 Hz to 525 MHz. Sensitivity: 25 mV rms (15 mV rms typical) (Input 2). Power Meter specs; Frequency range: 10 - 26.5 GHz, Power range: -70 dBm - +20 dBm, (sensor dependent).



 

Standard Calibration $470.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 5348A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 5348A CALIBRATION and/or Keysight (Agilent) 5348A 26.5 GHz Microwave Counter/Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: