Keysight (Agilent) 5361B CALIBRATION and Keysight (Agilent) 5361B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 5361B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 5361B   Description / Specification:    
Keysight (Agilent) 5361B Pulse/CW Microwave Frequency Counter

The HP 5361B is a Pulse/CW Microwave Counter that was designed for both high precision pulse and CW performance. It is the only pulse/CW microwave counter with frequency modulation profiling built in. Characterize radar, EW, and communications systems or components. Lowers your equipment costs by eliminating the need for a separate CW counter, pulse generator, and computer. The HP 5361B measures 40 GHz pulsed microwave signals with up to 1 Hz resolution. Six separate pulse microwave measurements are available to characterize your signals: frequency, PRF, PRJ, pulse width, off-time, and frequency profiling. The 5361B has as range of 500 MHz to 20 GHz, / 26.5 GHz (opt. 026)/ 40 GHz (opt. 040);(Input 1); 10 Hz to 525 MHz (Input 2), CW signals from 20 GHz to 10 Hz with 1 Hz resolution. Resolution improves to 0.001 Hz at 100 kHz., 40 GHz pulsed microwave signals with up to 1 Hz resolution.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 5361B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 5361B CALIBRATION and/or Keysight (Agilent) 5361B Pulse/CW Microwave Frequency Counter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: