Keysight (Agilent) 5361B CALIBRATION and Keysight (Agilent) 5361B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 5361B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 5361B   Description / Specification:    
Keysight (Agilent) 5361B Pulse/CW Microwave Frequency Counter

The HP 5361B is a Pulse/CW Microwave Counter that was designed for both high precision pulse and CW performance. It is the only pulse/CW microwave counter with frequency modulation profiling built in. Characterize radar, EW, and communications systems or components. Lowers your equipment costs by eliminating the need for a separate CW counter, pulse generator, and computer. The HP 5361B measures 40 GHz pulsed microwave signals with up to 1 Hz resolution. Six separate pulse microwave measurements are available to characterize your signals: frequency, PRF, PRJ, pulse width, off-time, and frequency profiling. The 5361B has as range of 500 MHz to 20 GHz, / 26.5 GHz (opt. 026)/ 40 GHz (opt. 040);(Input 1); 10 Hz to 525 MHz (Input 2), CW signals from 20 GHz to 10 Hz with 1 Hz resolution. Resolution improves to 0.001 Hz at 100 kHz., 40 GHz pulsed microwave signals with up to 1 Hz resolution.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 5361B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 5361B CALIBRATION and/or Keysight (Agilent) 5361B Pulse/CW Microwave Frequency Counter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: