Keysight (Agilent) 54505B CALIBRATION and Keysight (Agilent) 54505B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54505B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54505B   Description / Specification:    
Keysight (Agilent) 54505B 2 Ch 300 MHz Digitizing Oscilloscope

The HP 54505B is a 300 MHz, 500 MSa/s sample rate, 2-channel digitizing oscilloscope. Use it to trigger on a wide variety of user-specified conditions. Trigger on edge, pattern, state, or trigger after delay to capture such elusive events as timing violations or transient bus phenomena. To pinpoint infrequent events and determine their cause, use HP's advanced logic triggering in conjunction with up to four channels to quickly isolate anomalies. Triggering on an anomaly will allow you to probe other points within the system during the failure condition to understand the cause of tbe problem quickly. If you are characterizing several events separated in time, the sequential single-shot capability allows you to capture the pulses without dead time in between. You can then analyze the pulses individually or all together in normal, averaged, or envelope mode. Specifications. Repetitive Bandwidth: 300 MHz (equivalent time). Number of channels (simultaneous acquisition): 2. Vertical sensitivity range: 1 mV/div to 5 V/div. Vertical dc gain Accuracy: ± 1.25% of full scale. Vertical resolution: 8 bits (10 bits via HP-IB with averaging). Maximum sample rate (Real time mode): 500 MSa/s on all channels). Waveform record length: 8001 points (real-time), 501 points (repetitive). Maximum input: 1 M-ohm: ± 250 V [dc + peak ac < 10kHz)], 50 ohm: 5 V rms. Time base range: 1 ns/div to 5 s/div. Resolution: 20 ps. Trigger Pulse width (minimum): Internal 1.75 ns, External 2.8 ns.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54505B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 54505B CALIBRATION and/or Keysight (Agilent) 54505B 2 Ch 300 MHz Digitizing Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: