Keysight (Agilent) 54540C CALIBRATION and Keysight (Agilent) 54540C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54540C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54540C   Description / Specification:    
Keysight (Agilent) 54540C 4 Ch 500 MHz Digitizing Oscilloscope

The HP 54540C is a 500 MHz, 2 GSa/s sample rate, 4-channel digitizing oscilloscope. It has all of the features that you would expect in a scope plus more. Use sequential single-shot when you need to capture successive single-shot events without capturing the dead time in between. It is a great tool for applications such as pulsed laser research, high-energy physics, and pulse echo. Use glitch trigger to find the causes of anomalies in circuit operation. Trigger on hard-to-see narrow glitches down to 1 ns wide. Waveforms can be saved and time-stamped upon failure of either wave form compare or limit test. Up to 665 failures of 500 points each can be stored in multiple memory and sent to a printer, plotter, or a computer via HP-IB. Specifications. Repetitive Bandwidth: 500 MHz (equivalent time). Real-time bandwidth: 500 MHz (1 channel on), 250 MHz (2 channels on), 125 MHz (3 or 4 channels on). Number of channels (all are simultaneous acquisition): 4. Vertical sensitivity range: 1 mV/div to 5 V/div. Vertical dc gain Accuracy: ± 1.25% of full scale. Vertical resolution: 8 bits (10 bits via HP-IB with averaging). Maximum sample rate (Real time mode): 2 GSa/s (1 channel on), 1 GSa/s (2 channels on), 500 MSa/s (3 or 4 channels on). Maximum sample rate (Repetitive mode): 1 GSa/s. Waveform record length: 32,768 points (real-time), 501 points (repetitive). Maximum input: 1 M-ohm: ± 250 V (dc + ac) [ac<10 kHz], 50 ohm: 5 V rms. Time base range: 500 ps/div to 5 s/div. Resolution: 10 ps. Trigger Pulse width (minimum) 1 ns. Color Display. Opt 001 Telecommunications Mask Test Software.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54540C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 54540C CALIBRATION and/or Keysight (Agilent) 54540C 4 Ch 500 MHz Digitizing Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.