Keysight (Agilent) 54645D CALIBRATION and Keysight (Agilent) 54645D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54645D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54645D   Description / Specification:    
Keysight (Agilent) 54645D 18 Ch 100 MHz Mixed Signal Oscilloscope

The HP 54645D mixed-signal oscilloscope (MSO) provides the triggering power you need to solve your toughest mixed-signal problems in an easy-to-use control system. You no longer need to regulate powerful triggering features such as pattern and glitch to special situations. Because the MSO is an oscilloscope, you will find it ideally suited for everyday use with its simple edge triggering. This is the familiar scope triggering mode and it is the one that will solve most of your problems. You can trigger on a rising or falling edge on any of the MSO’s 18 input channels. Pattern triggering is provided to allow you to set up a pattern of high, low and don’t-care levels across any or all of the MSO’s 18 channels. In the scope channels, the threshold which determines high or low levels is the scope trigger level. Specifications. Scope Channels: Ch. 1 and Ch. 2. Bandwidth (3dB): dc to100 MHz @ >= 10 mv/div (> 75 Mhz @ < 10 mv/div), ac Coupled: 1.5 Hz to 100 MHz. Rise Time (calculated): ~ 3.5 ns @ > 10 mv/div (< 4.6 ns @ < 10 mv/div). Input Resistance: 1 Mohm. Input Capacitance: ~13 pF. Maximum Input: 400 V (dc + peak ac). Range: 1 mV/div to 5 V/div. 16 channels (0-15) in two pods of 8 channels each Maximum Input Voltage: ± 40 volts peak. Threshold Range: ± 6.0 volts in 50 mV increments. Threshold Accuracy: ± (100 mV + 3% of threshold setting). Sweep Speeds: 50 s/div to 5 ns/div main and delayed. Accuracy: ± 0.01%. Horizontal Resolution: 40 ps. Trigger Modes: Auto, Autolevel, and Normal. Holdoff: ~ 200 ns to ~ 25 seconds. Polarity: Rising or falling. Minimum Pulse Width Setting: 8 ns. Maximum Sampling Rate: 400 MSa/s on one pod, 200 MSa/s on two pods. Maximum Memory Depth: 2 MB samples per channel on one pod, 1 MB samples when both pods are used. Display: 7-inch raster monochrome CRT. Opt 001: RS-03 Magnetic Interference shielding added to the CRT. Opt 002: RE-02 Display Shield added to the CRT to reduce radiated interference.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54645D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 54645D CALIBRATION and/or Keysight (Agilent) 54645D 18 Ch 100 MHz Mixed Signal Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: