Keysight (Agilent) 54845A REPAIR and Keysight (Agilent) 54845A CALIBRATION

The Keysight (Agilent) 54845A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 54845A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54845A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54845A   Description / Specification:   Spec Sheet 
Keysight (Agilent) 54845A 4 Ch 1.5 GHz Infiniium Oscilloscope

The Agilent 54845A 4 Ch 1.5 GHz Infiniium Oscilloscope combines a simple, analog-like front panel, a familiar Windows-based graphical user interface, and a built-in information system. Dedicated scale and offset knobs for each vertical channel, color coded with the waveform colors, provide intuitive scope operation. Backlit LEDs on the front panel show at a glance how the scope is set up. A single QuickMeas button gives you four of your favorite measurements with statistics at the push of a button. Infiniium’s built-in information system puts measurement assistance at your fingertips. A Setup Guide walks you step-by-step through making more than 20 common complex measurements like jitter and runt triggering. In addition, context-sensitive help is available to define all features available in the Windows dialog boxes. In addition to the standard trigger modes such as edge, glitch, pattern, state, delay, video and line, Agilent’s violation trigger adds capabilities such as runt trigger, setup/hold time trigger, pulse width trigger, and transition trigger to capture those elusive violations. And, Infiniium’s graphical dialog boxes make it easy to set up advanced trigger conditions. Specifications. Bandwidth: 1.5 GHz. Channels: 4. Sample Rate: 2 ch. mode: 8 GSa/s | 4 ch. mode: 4 GSa/s. Memory/Channel: 2 ch. mode: 64K | 4 ch. mode: 32K. Vertical Resolution: 8 bits; 12 bits or greater with averaging. Sensitivity: 1 M ohm: 2 mV/div to 2 V/div | 50 ohm: 2 mV/div to 1 V/div. Input Impedance: 1 M ohm ±1% (~12pF) or 50 ohm ±1.5%. Timebase Range: 100 ps/div to 20 s/div. Trigger Enhancements: Edge, glitch, pattern, state, delay by time, delay by events, video, line, violation (runt, setup/hold time, pulse width, transition). Display: Large 8.4-inch color active matrix LCD display. I/O: 10/100 Mbps LAN, GPIB, RS-232, and Centronics. Options. Opt 001, Provides additional standard probes (2 1161A probes). Opt 002, Add 1 1162A 1:1 passive probe. Opt 003, Add 1 1163A 10:1 500 ohm, low C passive probe. Opt 006, Add 1 1152A 2.5 GHz, 0.6 pF active probe. Opt 008, Add 1 1153A 200 MHz differential probe. Opt 009, Add 1 1154A 500 MHz differential probe. Opt 010, Add 1 1159A 1 GHz differential probe. Opt 100, Communication Mask Test Kit (E2625A). Opt 200, Voice Control for Infiniium oscilloscopes.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54845A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 54845A REPAIR and/or Keysight (Agilent) 54845A 4 Ch 1.5 GHz Infiniium Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: