Keysight (Agilent) 6038A CALIBRATION and Keysight (Agilent) 6038A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 6038A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 6038A   Description / Specification:    
Keysight (Agilent) 6038A 60V 10A Single-Output Autoranging DC Power Supply

The Agilent 6038A Single-Output Autoranging Power Supply is part of the 601x series of autoranging power supplies which provide maximum power over a wide range of voltage and current combinations without having to manually select the proper output range. Specifications. Voltage: 0 to 60 V. Current: 0 to 10 A. Maximum power: 240 W. Autoranging output V1, P1: 60 V, 3.3 A. Autoranging output V2, P2: 40 V, 6 A. Autoranging output V3, P3: 20 V, 10 A. Programming accuracy Voltage (at 25° C ±5° C): 0.035% +40 mV. Programming accuracy Current (at 25° C ±5° C): 0.09% +10 mA. Ripple and noise, Voltage (20 Hz to 20 MHz): 3 mV (rms), 30mV (p-p). Ripple and noise, Current (20 Hz to 20 MHz): 5 mA. Load regulation Voltage: 0.01%+ 3 mV. Load regulation Current: 0.01%+ 5 mA. Transient response time (10% step change): 1 ms. Transient response time level (10% step change): 75 mV. dc floating voltage (either terminal can be grounded or floated from chassis ground): ±240 V. Remote Sensing: Up to 2 V drop in each lead. Voltage regulation degrades for greater than 0.5 V drop. Opt 001 Front panel has only line switch, line indicator, and OVP adjust.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 6038A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 6038A CALIBRATION and/or Keysight (Agilent) 6038A 60V 10A Single-Output Autoranging DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: