Keysight (Agilent) 60501A CALIBRATION and Keysight (Agilent) 60501A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 60501A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   Keysight (Agilent) 60501A   Description / Specification:    
Keysight (Agilent) 60501A 30 A, 150 W DC Electronic Load Module

The HP 60501A 150 Watt Single Input Load Module is used in applications such as over-voltage protection testing for power supplies, zero volt load simulation for testing batteries, and power pulse generation for testing power components require power supplies in the test system configuration. Specifications. DC input ratings: 0-30A, 3-60V, (current derated from 0-3V) power limited to 150W. Modes: constant current (CC), constant voltage (CV), and constant resistance (CR). Programmable ranges: CC mode: 0-3A, 0-30A / CR mode: .067-2.0 ohm, 2-2000 ohm, 20-10000 ohm. Programming accuracy: ± 0.1 % ± 40 mA (in 30A CC range). Programming resolution: 8 mA (in 30A CC range). Programmable electronic short: 0.067 ohm (0.040 ohm typical). Readback resolution: 8 mA, 16 m V. Readback accuracy: 0.06% ± 40 mA, 0.05% ± 45 mV. Built-in pulse waveform generation: Frequency 0.25 Hz-10kHz, Duty cycle 6-94%, Slew rate 0.5 A/ms-2.5 A / us in 30A CC range. Analog programming: 0 to 10 V. Analog programming bandwidth: 10 kHz in CC mode.



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 60501A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 60501A CALIBRATION and/or Keysight (Agilent) 60501A 30 A, 150 W DC Electronic Load Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: