A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 60501B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   Keysight (Agilent) 60501B   Description / Specification:    
Keysight (Agilent) 60501B 30 A, 150 W DC Electronic Load Module

The HP 60501B dc electronic load is optimized to address a broad range of dynamic loading applications. They are specifically designed for stability in applications where fast transients are applied to the load inputs, such as during dc power supply startup characterization or transient response testing. Dynamic load performance can be further tailored to specific application needs with the programmable slew rate feature. The HP 60501B meets all specifications when operated above 3.0 V; however, the dc operating characteristics also extend below this minimum-input voltage for static tests. Because of the FET technology used in the power input circuits, HP electronic loads have a low minimum-input resistance allowing them to sink high currents even at low voltages. Specifications. Amperes: 0 to 30 A. Volts: 3 to 60 V. Maximum power (at 40° C): 150 W. Constant current mode Ranges: 0 to 3 A, 0 to 30 A. Constant current mode Accuracy: 0.1% ±40 mA. Constant current mode Regulation: 10 mA. Constant voltage mode Accuracy 0.1% ±50 mV. Constant voltage mode Regulation (w/remote sense): 5 mV. Constant resistance mode Ranges: 0.067 to 2 ohm, 2 to 2,000 ohms, 20 to 10,000 ohms. Transient generator Frequency range: 0.25 Hz to 10 kHz (3% Accuracy). Current readback accuracy: 0.06% ±40 mA. Power readback accuracy: 0.2% ±2 W. Ripple and noise (20-Hz to 10-MHz noise): 2 mA rms, 20 mA peak-to-peak (Current), 5 mV rms (Voltage).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 60501B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your Keysight (Agilent) 60501B CALIBRATION and/or Keysight (Agilent) 60501B 30 A, 150 W DC Electronic Load Module REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: