Keysight (Agilent) 60504A CALIBRATION and Keysight (Agilent) 60504A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 60504A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   Keysight (Agilent) 60504A   Description / Specification:    
Keysight (Agilent) 60504A 120 A, 600 W DC Electronic Load Module

The HP 60504A 600 Watt Single Input Load Module is used in applications such as over-voltage protection testing for power supplies, zero volt load simulation for testing batteries, and power pulse generation for testing power components require power supplies in the test system configuration. Specifications. DC input ratings: 0-120A, 3-60V, (current derated from 0-3V) power limited to 600W. Modes: constant current (CC), constant voltage (CV), and constant resistance (CR). Programmable ranges: CC mode: 0-12A, 0-1 20A / CR mode: 0.017-0.5 ohm, 0.5-500 ohm, 5-5000 ohm. Programming accuracy: ± 0.12% ± 130 mA (in 120A CC range). Programming resolution: 32 mA (in 120 A CC range). Programmable electronic short: 0.017 ohm (0.012 ohm typical). Readback resolution: 32 mA, 16 mV. Readback accuracy: 0.1% ± 110 mA, 0.1% ± 45 mV. Built-in pulse waveform generation: Frequency 0.25 Hz to 10kHz, Duty cycle 6 to 94%, Slew rate 2 A/ ms-10 A / us in 120A CC range. Analog programming: 0 to 10 V. Analog programming bandwidth: 10 kHz in CC mode.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 60504A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 60504A CALIBRATION and/or Keysight (Agilent) 60504A 120 A, 600 W DC Electronic Load Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: