A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 6060B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   Keysight (Agilent) 6060B   Description / Specification:    
Keysight (Agilent) 6060B 60 A, 300 W Single Input Electronic Load

The Agilent 6060B is a single-input dc electronic load. It meets all specifications when operated above 3V; however, the dc operating characteristics also extend below this minimum-input voltage for static tests. The figure below shows the operating range of a typical HP dc electronic load. Low voltage operation, down to zero volts, is possible at correspondingly-reduced current levels, depending on the minimum resistance of the load. HP electronic loads, therefore, can be used in many applications that previously required zero-volt loads. Specifications. Amperes: 0 to 60 A. Volts: 3 to 60 V. Maximum power (at 40° C): 300 W. Constant current mode Ranges: 0 to 6 A, 0 to 60 A. Constant current mode Accuracy: 0.1% ±75 mA. Constant current mode Regulation: 10 mA. Constant voltage mode Accuracy 0.1% ±50 mV. Constant voltage mode Regulation (w/remote sense): 10 mV. Constant resistance mode Ranges: 0.033 to 1.0 ohm, 1 to 1,000 ohms, 10 to 10,000 ohms. Transient generator Frequency range: 0.25 Hz to 10 kHz (3% Accuracy). Current readback accuracy: 0.05% ±65 mA. Power readback accuracy: 0.2% ±4 W. Ripple and noise (20-Hz to 10-MHz noise): 4 mA rms, 40 mA peak-to-peak (Current), 6 mV rms (Voltage).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 6060B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 6060B CALIBRATION and/or Keysight (Agilent) 6060B 60 A, 300 W Single Input Electronic Load REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: