Keysight (Agilent) 6205C CALIBRATION and Keysight (Agilent) 6205C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 6205C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 6205C   Description / Specification:    
Keysight (Agilent) 6205C Dual Output Dual Range DC Power Supply

The HP 6205C Dual Output Dual Range DC Power Supply is equipped with ten-turn output voltage controls, volt/ampere meter, meter function/ range switch, and front and rear output termina ls. In addition, an output range switch permits the selection of either a high or a low output voltage range. Model 6205C combines the versatility of a dual power supply with the flexibility of auto-parallel and auto-series operation to extend the output ratings of this supply to 20 V / 1.2 A, 40 V /0.6 A, and 80 V / 0.3 A. In addition, using the supply's auto-tracking capability, opposite polarity voltages (±20 V, ±40 V) can conveniently be obtained from this one supply. This constant voltage/current limiting supply is short-circuit protected by a fixed current limiting circuit which is activated at approximately 110% of rated load current. The current-limit point can be reduced by changing the value of a single internal resistor. Units may be bench operated or rack mounted individually or in pairs using accessory rack mounting hardware. DC Output; 0-20/0-40 and 0-20/0-40 V, 0-0.6/0.3 and 0-0.6/0.3. Load effect: 0.01% + 4 mV. Source effect: 0.01% +4 mV. PARD rms/ p-p: 200 uV/ 1 mV. Control Mode and Resolution: CV/CL, 10 mV. Remote Control Coefficients: 200 ohm/V ±1%. Options. Opt 011: internal overvoltage protection crowbar. Protects delicate loads against power supply failure or operator error. Opt 028: 230 Vac ± 10%, single phase input. Consists of reconnecting power transformer taps, and other components where necessary. Opt 040: Multiprogrammer interface, Prepares HP 6205C power supplies for resistance programming by the HP 6940B or 6942A Multiprogrammer.



 

Standard Calibration $145.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 6205C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 6205C CALIBRATION and/or Keysight (Agilent) 6205C Dual Output Dual Range DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: