Keysight (Agilent) 6235A CALIBRATION and Keysight (Agilent) 6235A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 6235A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 6235A   Description / Specification:    
Keysight (Agilent) 6235A Triple Output Power Supply

The HP 6235A Triple Output Power Supply delivers three adjustable dc output voltages: 0 to +6 V at 1 A, 0 to + 18 V at 0.2 A, and 0 to -18 V at 0.2 A. A single 0 to 36 volt output at 0.2 A can also be obtained by connecting across the + 18 V and -18 V terminals. The controls, meter, and binding posts are conveniently arranged on the front panel. One voltage control simultaneously adjusts the + 18 V and -18 V outputs, which track one another and can be used to power operational amplifiers and other circuits requiring balanced positive and negative voltages. The supply's dual outputs have added versatility with an adjustable tracking ratio control (TRACK) that can set the negative output to a lower voltage than the positive output. Once the trackmg ratio control has established a voltage ratio between the positive and negative outputs, the ratio remains constant as the + 18 V voltage control is adjusted. A third control sets the 0 to +6 V output voltage. The supply is a constant voltage/current limit type with each output voltage continuously adjustable over its range, while the maximum current available is automatically limited to prevent over loading. The power supply's outputs share a common terminal and are isolated from chassis ground so that any output terminal can be grounded if desired . Each output voltage or current can be quickly selected and monitored With the push-button meter switches. Specifications. Output: 0 to +6 V at 1 A, 0 to + 18 V at 0.2 A, 0 to -18 V at 0.2 A. Load effect: 8 mV @ 0 to +6 V, 10 mV @ 0 to 18 V. Source effect: 8 mV @ 0 to +6 V, 15 mV @ 0 to 18 V. PARD rms/p-p: 1 mV/5 mV. Control Mode and Resolution: CV/CL.



 

Standard Calibration $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 6235A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 6235A CALIBRATION and/or Keysight (Agilent) 6235A Triple Output Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: