Keysight (Agilent) 66104A CALIBRATION and Keysight (Agilent) 66104A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 66104A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 66104A   Description / Specification:    
Keysight (Agilent) 66104A 60V 2.5A Single Output DC Power Module

The Agilent 66104A DC Power Plug-in Module's output is designed for automated testing that helps meet changing requirements in ATE and production test with a modular design that conserves rack space and simplifies system cabling and assembly. The Agilent 66104A is used with the 66000A mainframe. Specifications. Output voltage: 0 to 60 V. Output current: 0 to 2.5 A. Maximum power: 150 W. Programming accuracy at 25 °C ± 5 °C: Voltage 0.03% + 27 mV, Current 0.03% + 1.2 mA. Readback accuracy (via GPIB or keyboard display at 25 °C ± 5 °C): Voltage 0.02% + 16 mV, Current 0.02% + 1 mA. Ripple and noise from 20 Hz to 20 MHz Constant voltage: rms 9 mV, peak-to-peak 15 mV. Ripple and noise from 20 Hz to 20 MHz Constant current: rms 1 mA. Line regulation: Voltage 2 mV, Current 0.1 mA. Load regulation: Voltage 2 mV, Current 0.1 mA. Transient response time: Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any step change in load current up to 10 percent of the power module rated output current. OVP accuracy (characteristic): 250 mV. Options. Opt 760, Adds isolation/polarity relays. Opt J17, External monitor.



 

Standard Calibration $190.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 66104A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 66104A CALIBRATION and/or Keysight (Agilent) 66104A 60V 2.5A Single Output DC Power Module REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: