Keysight (Agilent) 6622A REPAIR and Keysight (Agilent) 6622A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 6622A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 6622A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 6622A   Description / Specification:   Spec Sheet 
Keysight (Agilent) 6622A Dual-Output Dual-range DC System Power Supply

The Agilent 6622A Dual-Output Dual-range DC System Power Supply offers fast, low-noise outputs; built-in measurements and advanced programmable features; and protection features to ensure DUT safety. Supplemental characteristics. DC floating voltage: Output terminals can be floated up to ± 240 VDC from chassis ground. Remote sensing: Up to 1 V drop per load lead. The drop in the load leads subtracts from the voltage available for the load. Command processing time: 7 ms typical with front-panel display disabled. Output programming: Current sink limits are fixed approximately 10% higher than source limits for a given operating voltage above 2.5 V. Specifications. DC Outputs: Two, 0 to 20 V / 0 to 4 A or 0 to 50 V / 0 to 2 A. Power: 80 W. Programming Accuracy (Voltage / Current): 0.06% + 50 mV / 0.16% + 40 mA. Readback Accuracy (Voltage / +Current / -Current): 0.05% + 50 mV / 0.1% + 8 mA / 0.2% + 20 mA. Ripple and Noise (peak-to-peak, 20 Hz to 20 MHz; rms, 20 Hz to 10 MHz); Constant voltage rms: 500 µV. peak-to-peak: 3 mV. Constant current rms: 1 mA. Load Regulation (Voltage / Current): 2 mV / 1 mA. Line Regulation (Voltage / Current): 1 mV / 1 mA. Transient response time: Less than 75 µs for the output to recover to within 75 mV of nominal value following a load change within specifications.



 

Standard Calibration $190.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 6622A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 6622A REPAIR and/or Keysight (Agilent) 6622A Dual-Output Dual-range DC System Power Supply CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: