The Agilent 6623A Triple-Output Dual-range DC System Power Supply offers fast, low-noise outputs; built-in measurements and advanced programmable features; and protection features to ensure DUT safety. Supplemental characteristics. DC floating voltage: Output terminals can be floated up to ± 240 VDC from chassis ground. Remote sensing: Up to 1 V drop per load lead. The drop in the load leads subtracts from the voltage available for the load. Command processing time: 7 ms typical with front-panel display disabled. Output programming: Current sink limits are fixed approximately 10% higher than source limits for a given operating voltage above 2.5 V. Specifications. DC Outputs: One, 0 to 7 V / 0 to 5 A or 0 to 20 V / 0 to 2 A; One, 0 to 20 V / 0 to 2 A or 0 to 50 V / 0 to 0.8 A; One, 0 to 7 V / 0 to 10 A or 0 to 20 V / 0 to 4 A. Power: 40 / 80W. Programming Accuracy (Voltage / Current): 0.06% + 19 mV (@7 / 20 V), 0.06%+ 50 mV (@20 / 50 V) / 0.16% + 50 mA (@5 / 2A), 0.16% + 20 mA (@2 / 0.8A), 0.16% + 100 mA (@10 / 4A). Readback Accuracy (Voltage / +Current / -Current): 0.05% + 20 mV (@7 / 20 V), 0.05% + 50 mV (@20 / 50 V) / 0.1% + 10 mA (@5 / 2A), 0.1% + 4 mA (@2 / 0.8A), 0.1% + 20 mA (@10 / 4A) / 0.2% + 25 mA (@5 / 2A), 0.2% + 8 mA (@2 / 0.8A), 0.2% + 50 mA (@10 / 4A). Ripple and Noise (peak-to-peak, 20 Hz to 20 MHz; rms, 20 Hz to 10 MHz); Constant voltage rms: 500 µV. peak-to-peak: 3 mV. Constant current rms: 1 mA. Load Regulation (Voltage / Current): 2 mV / 1 mA (@5 / 2A), 0.5 mA (@2 / 0.8A), 2 mA (@10 / 4A). Line Regulation (Voltage / Current): 1 mV / 1 mA. Transient response time: Less than 75 µs for the output to recover to within 75 mV of nominal value following a load change within specifications.
|