Keysight (Agilent) 6632A REPAIR and Keysight (Agilent) 6632A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 6632A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 6632A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 6632A   Description / Specification:    
Keysight (Agilent) 6632A 20V 5A Single Output DC Power Supply

The HP 6632A is a 100 Watt, single output, series pass regulated power supplies optimized for systems applications. It provides a high performance output with a full set of programmable features. Both the voltage and current output can be programmed for either CV or CC operation. A built-in DVM and precision current shunt measure (read back) the actual power supply output. The internal HP-IB interface allows for complete programmability, including status reporting and interrupt generation with user designated fault conditions. In addition, programming commands (such as VSET for voltage programming) are easy-to-use and self-documenting. The HP 6632A sinks as well as sources current. This provides very fast down programming times and speeds throughput in production test applications. The negative current setting tracks the user-programmed positive current (CC) setting. Remote sense terminals allow for precise voltage regulation at the load. This feature will compensate for load lead IR drops of up to 2 volts per lead. The HP 6632A has Overvoltage and Overcurrent protection. Both features are programmable via the front panel keypad and HP·IB. The Overvoltage protection includes an SCR crowbar. Specifications. Volts: 0 to 20 V. Amps: 0 to 5 Amp. Load Effect (Load Regulation), for a load change from zero to maximum rated voltage or current of the supply: Voltage 2 mV, Current 1 mA. Source Effect (Line Regulation), given for any change within the rated line voltage for any output within the rated output voltage, current, and power of the supply: Voltage 0.5 mV, Current 0.5 mA. Ripple and Noise (PARD) rms / peak-peak (20 Hz - 20 MHz): Voltage (Normal) 0.3 mV / 3 mV, Voltage (Fast) 1 mV / 10 mV, Current (rms) 2 mA. Drift (Stability), change in output over 8-hour interval under constant line, load, and ambient temperature following 30-minute warm-up: Voltage 0.01% +0.5 mV, Current 0.01 % + 1 mA. Load Effect Transient Recovery, maximum time required for output voltage to recover within a band of 0.1 % of rated voltage around the nominal voltage followini! a 50% change in load current: Normal 100 us, Fast 50us. Minimum CC programming current: 20 mA. Voltmeter (25±5°C): Resolution 5 mV, Accuracy 0.07% + 15 mV. Ammeter (25±5°C): Resolution 1.25 mA, Accuracy 0.18% + 9 mA. DC Output Isolation: ±240 Vdc. Options. Opt 020: Front output binding posts. Opt 760: Isolation and polarity reversal relay.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 6632A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 6632A REPAIR and/or Keysight (Agilent) 6632A 20V 5A Single Output DC Power Supply CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: