Keysight (Agilent) 6653A CALIBRATION and Keysight (Agilent) 6653A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 6653A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 6653A   Description / Specification:    
Keysight (Agilent) 6653A 35V 15A Single Output System DC Power Supply

The Agilent 6653A is a 0-35 VDC / 0-15 A, Single-Output, Remote Sensing, (GPIB) Power Supply. Features, DC Floating Voltage: Output terminals can be floated up to ±240 Vdc from chassis ground. Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load lead subtracts from the voltage available for the load. Add 3 mV to the voltage load regulation specification for each 1-V change in the positive output lead due to load current change. Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the HP-IB. Output Programming Response Time: The rise and fall time (10/90% and 90 / 10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms. Modulation: (Analog programming of output voltage and current). Input Signal: 0 to -5V. Input Impedance: 10 k Ohm nominal. Input Power: 1.380 VA, 1,100 W at full load; 120 W at no load. Specifications. Output voltage: 0 to 35 V. Output current: 0 to 15 A. Programming accuracy (at 25° C ±5° C) Voltage: 0.06% + 15 mV. Programming accuracy (at 25° C ±5° C) Current: 0.15% + 13 mA. Ripple and noise (from 20 Hz to 20 MHz) Constant Voltage: 400 µV (RMS), 4 mV (peak-peak). Ripple and noise (from 20 Hz to 20 MHz) Constant Current: 5 mA (RMS). Readback accuracy at 25° C ±5° C: Voltage 0.07% + 25 mV / +Current 0.15% + 15 mA / -Current 0.35% + 24 mA. Load Regulation: Voltage 3 mV / Current 0.5 mA. Line Regulation: Voltage 1 mV / Current 0.75 mA. Transient Response Time: Less than 100 µs for the output voltage to recover to its previous level (within 0.1 % of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 6653A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 6653A CALIBRATION and/or Keysight (Agilent) 6653A 35V 15A Single Output System DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: