Keysight (Agilent) E1410A CALIBRATION and Keysight (Agilent) E1410A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E1410A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   Keysight (Agilent) E1410A   Description / Specification:    
Keysight (Agilent) E1410A 6.5 Digit Multimeter, VXI

The HP / Agilent E1410A 6.5-Digit VXI Multimeter provides high-accuracy in a 1-Slot, C-Size, message based module. VDC/VAC, 2- & 4- wire Ohm, True RMS from 20 Hz to 1 MHz, Noise rejection with long integration times/guarding, quality measurements with high common mode rejection, DC Voltage Ranges: 30mV, 300mV, 3V, 30V, 300V; DC Voltage Accuracy: 30 mV range 0.004% + 3.9 uV (20/16.7mS) and 0.0040% + 60 uV (10 uS), 300 mV range .0063% + 700 uV (20/16.7mS) and .0050% + 400 mV (10 uS), 4- Wire Resistance Ranges: 30 Ohm to 3 GOhm (9 ranges), 0.0065% + 4 mOhm to 1.6% + 100 kOhm accuracy, True RMS AC Voltage Ranges: 30 mV 0.58% + 37.3 uV (20 Hz to 45 Hz) to 300 V 1.08% + 390 mV (20 Hz to 100 kZ).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E1410A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) E1410A CALIBRATION and/or Keysight (Agilent) E1410A 6.5 Digit Multimeter, VXI REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: