Keysight (Agilent) 81630B REPAIR and Keysight (Agilent) 81630B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 81630B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 81630B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Power Sensor?
Shop for Comparable Products on our
 used Optical Power Sensor page or new Optical Power Sensor page

 
   Keysight (Agilent) 81630B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 81630B 970 to 1650 nm InGaAs Optical Power Sensor Module

The Agilent 81630B High Power Sensor Module is for use with Agilent 8163A/B Lightwave Multimeter, Agilent 8164A/B Lightwave Measurement System, and Agilent 8166A/B Lightwave Multichannel System. Specifications. Wavelength Range: 970 nm to 1650 nm. Power Range: +28 dBm to -70 dBm. Uncertainty (accuracy) at reference conditions: ±3% (1255 nm to 1630 nm). Linearity (power) at 23°C ±5°C: CW +28 dBm to -50 dBm (970 to 1630 nm) =±0.05 dB ± 1.2 nW. Return loss: >55 dB. Noise (peak to peak): <1.2 nW. Averaging time (minimal): 100 µs. Power Sensor Type: (InGaAs).



 

Standard Calibration $245.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 81630B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Absolute Wavelength Accuracy
Absolute Wavelength Accuracy is the maximum difference between the actual wavelength and the displayed wavelength of the Optical Source. Wavelength is defined as wavelength in vacuum.

Decibel (dB)
A unit of measurement of optical power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Nanometer (nm)
A unit of measure used to measure wavelength of light, meaning one one-billionth of a meter

Relative Intensity Noise (RIN)
Relative intensity noise (RIN), describes the instability in the power level of a laser. The noise term is important to describe lasers used in fiber-optic communication and LIDAR remote sensing. It is the square of the (spectrally resolved) RMS optical power amplitude divided by the measurement bandwidth and the square of the average optical power, expressed in dB/Hz.

Total Return loss
In an optical fiber, the loss that takes place at any discontinuity of refractive index, especially at an air-glass interface such as a fiber endface, at which a fraction of the optical signal is reflected back toward the source. RL = - 10log10 (Preflected/Preference)


Please contact us for your Keysight (Agilent) 81630B REPAIR and/or Keysight (Agilent) 81630B 970 to 1650 nm InGaAs Optical Power Sensor Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: