Keysight (Agilent) 83711B REPAIR and Keysight (Agilent) 83711B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 83711B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83711B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 83711B   Description / Specification:    
Keysight (Agilent) 83711B 20 GHz Synthesized CW Generator

The HP 83711B Synthesized CW Generator has fundamental oscillators and switched low-pass filters deliver < - 55 dBc harmonics, eliminate subharmonics, and suppress spurious to < - 60 dBc. These signal sources provide plenty of output power (typically > + 14 dBm), while spectral purity is maintained even at high power levels (typical output power at frequencies below 1 GHz is + 20 dBm). These signal sources deliver >100 dB dynamic range. Level resolution is 0.01 dB with typical accuracy of ± 1.0 dB at any frequency or power level. User Level Correction simplifies generating accurate, leveled power at distant test ports. The HP 83711B signal source is the recommended local oscillator for the HP 8970B noise figure meter. Low broadband noise minimizes errors in measurements of low gain devices. Use these signal sources with the HP 83550 series millimeter-wave modules to generate signals to 110 GHz. All front-panel functions are completely HP-IB-programmable and SCPI-compatible. Specifications. Frequency Range: 1.0 to 20 GHz. Frequency Resolution: 1 kHz, 1 Hz with Opt 1E8. Output Power (with Option 1E1): 1 to 18 GHz (+10 dBm), 18 to 20 GHz (+8 dBm). Resolution: 0.01 dB. Accuracy (-4 dBm to maximum specified leveled output power): 1.0 to 20 GHz, ±1.0 dB. Harmonics: < -50 dBc (at levels < +10 dBm). Sub-Harmonics: None. Non-Harmonic Spurious (>3 kHz): -60 dBc. Options. Opt 1E1: Add 110 dB Output Step Attenuator. Opt 1E2: Add High-Performance Modulation Generator. Opt 1E5: Add High-Stability Timebase. Opt 1E8: Add 1 Hz Frequency Resolution. Opt 1E9: 3.5 mm RF Output Connector.



 

Standard Calibration $515.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83711B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 83711B REPAIR and/or Keysight (Agilent) 83711B 20 GHz Synthesized CW Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: