Keysight (Agilent) 8407A CALIBRATION and Keysight (Agilent) 8407A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8407A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8407A   Description / Specification:    
Keysight (Agilent) 8407A 110 MHz Two Input Tracking Receiver

The HP 8407A is a two input tracking receiver, using both inputs (reference and test channels) to form their magnitude ratio and phase difference before routing to display. Specifications. Frequency range: 0.1 - 110 MHz. Impedance: 50 ohm, SWR < 1.08; Option 008 : 75 ohm, SWR < 1.08. Dynamic range: 80 dB. Test Input: DIRECT -10 to -90 dBm signal range. ATTENUATED, +20 to -50 dBm signal range. Damage level +26 dBm/ 50 V dc. Reference input: DIRECT level required, -10 to -60 dBm. ATTENUATED level required +20 to -20 dBm. Damage level +26 dBm/ 50 V dc . Amplitude accuracy: FREQUENCY RESPONSE ±0.2 dB for DIRECT input (test input > -60 dBm), 0.1- 110 MHz; ±0.05 dB over any 10 MHz portion; may be calibrated out. Typically ± 0.05 dB for DIRECT inputs (REFERENCE level of - 10 dBm) . DISPLAY REFERENCE, < 0.05 dB/ 1 dB step, total error <= 0.1 dB; < 0.1 dB/ 10 dB step, total error <= 0.25 dB. ATTENUATED INPUTS, 40 dB ±0.5 dB. REFERENCE CHANNEL GAIN CONTROL, 20 dB and 40 dB steps ± 0.5 dB/ step. CROSSTALK, < 0.03 dB when test / ref = -40 dB to < 4 dB when test/ ref = -80dB.



 

Standard Calibration $780.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8407A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Spurious Signals
Spurious signals are undesired signals. They can be considered in two classes. They can be stationary; their frequency and amplitude do not change significantly, or non-stationary, where the frequency and/or amplitude change significantly over short time periods.


Please contact us for your Keysight (Agilent) 8407A CALIBRATION and/or Keysight (Agilent) 8407A 110 MHz Two Input Tracking Receiver REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: