Keysight (Agilent) 8487D CALIBRATION and Keysight (Agilent) 8487D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8487D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   Keysight (Agilent) 8487D   Description / Specification:    
Keysight (Agilent) 8487D 50 GHz High-sensitivity Diode Power Sensor

The Agilent 8487D Diode power sensor provides extraordinary accuracy, stability and SWR over a wide range of frequencies. Specifications. Frequency range: 50 MHz to 50 GHz. Maximum SWR: 0.05 GHz to 0.1 GHz (1.19), 0.1 GHz to 2 GHz (1.15), 2 GHz to 12.4 GHz (1.20), 12.4 GHz to 18 GHz (1.29), 18 GHz to 34 GHz (1.37), 34 GHz to 40 GHz (1.61), 40 GHz to 50 GHz (1.89). Power linearity (Negligible deviation except for those power ranges noted.): –30 dBm to –20 dBm: (±2%). Maximum power: 100 mW avg, 100 mW pk, 10 W µs per pulse. Connector type: 2.4 mm (m).



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8487D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your Keysight (Agilent) 8487D CALIBRATION and/or Keysight (Agilent) 8487D 50 GHz High-sensitivity Diode Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: