Keysight (Agilent) 8493B CALIBRATION and Keysight (Agilent) 8493B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8493B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Attenuator?
Shop for Comparable Products on our
 used RF Attenuator page

 
   Keysight (Agilent) 8493B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 8493B SMA Coaxial Fixed Attenuator

The Agilent 8493B RF attenuator is furnished with SMA type connectors. The connectors are heat treated beryllium copper for greater strength and wear. The HP 8493B attenuator achieves a flat frequency response (typically a few hundredths of a dB) and overall accuracy (typically ±2 % of value in dB at 26.5 GHz) through the use of thin-film attenuator cards. Attenuation is option specific. Specifications. Frequency range: dc to 18 GHz. Attenuation accuracy: 3 dB ±0.3 dB, 6 dB ±0.4 dB, 10 dB ±0.6 dB, 20 dB ±1.0 dB, 30 dB ±1.0 dB. Temperature stability: 0.0001 dB/dB/°C. Maximum input power: 2 W avg., 100 W peak. Power sensitivity: 0.001 dB/dB/W. Option 003 3 dB. Option 006 6 dB. Option 010 10 dB. Option 020 20 dB. Option 030 30 dB.



 

Standard Calibration $225.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8493B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 8493B CALIBRATION and/or Keysight (Agilent) 8493B SMA Coaxial Fixed Attenuator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: