Keysight (Agilent) 85037B CALIBRATION and Keysight (Agilent) 85037B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 85037B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Component?
Shop for Comparable Products on our
 used RF Component page or new RF Component page

 
   Keysight (Agilent) 85037B   Description / Specification:    
Keysight (Agilent) 85037B Precision Detector

The HP 85037B precision detector is designed specifically for operation with the HP 8757D scalar network analyzer and may be used in either ac or dc detection modes. These dual diode detectors contain internal frequency correction factors in an internal EE PROM (read automatically by the HP 8757D) for improved measurement accuracy versus frequency. When used in conjunction with the HP 8757D’s internal power calibrator (Option 002), these detectors provide the maximum absolute power measurement accuracy. The Agilent 85037B detector is not compatible with the HP 8757E. Specifications (Used with the 8757D). Frequency Range: 10 MHz to 26.5 GHz. Connector Type: 3.5 mm (m). Specifications Dynamic Range AC Mode; Frequency: 0.01 to 0.04 GHz. Return Loss: 10 dB. Frequency Response: ±0.35 dB. Power (at 50 MHz): 20 dBm. Dynamic Acccuracy: ±0.25 dB. Absolute Acccuracy: ±0.25 dB. Dynamic Range: AC Mode +20 to -55 dBm. Dynamic Range DC Mode +20 to -50 dBm Specifications Frequency, 0.01 to 0.04 GHz; Return Loss: 10 dB. Frequency Response: ±0.35 dB. Power (at 50 MHz): 20 dBm. Dynamic Acccuracy: ±0.25 dB. Absolute Acccuracy: ±0.25 dB. Specifications Frequency, 0.04 to 18.0 GHz; Return Loss: 20 dB. Frequency Response: ±0.18 dB. Power (at 50 MHz): 10 dBm. Dynamic Acccuracy: ±0.11 dB. Absolute Acccuracy: ±0.11 dB. Specifications Frequency, 18 to 26.5 GHz; Return Loss: 18 dB. Frequency Response: ±0.22 dB. Power (at 50 MHz): -30 dBm. Dynamic Acccuracy: ±0.11 dB. Absolute Acccuracy: ±0.11 dB.



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 85037B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 85037B CALIBRATION and/or Keysight (Agilent) 85037B Precision Detector REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: