Keysight (Agilent) 8503B CALIBRATION and Keysight (Agilent) 8503B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8503B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another S-Parameter Test Set?
Shop for Comparable Products on our
 used S-Parameter Test Set page

 
   Keysight (Agilent) 8503B   Description / Specification:    
Keysight (Agilent) 8503B 75 Ohm S-parameter Test Set

The HP 8503B 500 kHz to 1.3 GHz, 75 ohm, S Parameter Test Set, Measures reflection and transmission coefficients of a one-port or two-port device operating withing the frequency range of 500kHz to 1.3 GHz. Directivity: >40 dB, Frequency Response: Transmission: ±1 dB, ±12 degrees, from 0.5 to 1200 MHz, Reflection: ±2 dB, ±20 degrees, from 0.5 to 1300 MHz; ±15 degrees from 2 to 1300 MHz. Test Port 1&2: Frequency Range (MHz): 0.5 to 2, Return Loss: >18.0 dB (<1.29 SWR), 2 to 1300, >24 dB (<1.135 SWR), Open/Short Ratio: Frequency Range: 0.5 to 2, Magnitude: <±1.25 dB, Phase: <±10°, 2 to 1300, <±0.9 dB, <±7.5°, Reference Return Ports (R, A, B): Frequency Range (MHz): 0.5 to 2, Return Loss: >20 dB (<1.22 SWR), 2 to 1000, >23 dB (<1.15 SWR), 1000 to 1300, >20 dB (<1.22 SWR), RF Input Port: >20 dB Return Loss from 0.5 to 1300 MHz (<1.22 SWR), Maximum Operating Level: +20 dBm (100 mW), Insertion Loss: Input to Port 1&2: 19 dB Nominal, Input to Port A or B: 25 dB Nominal, Input to Port R: 19 dB Nominal, Transmission: <°0.5 dB Magnitude and <±4° Phase, Reflection: <±0.75 dB Magnitude and <±6°, RF Input to Test Port 1 or 2: <±1.5 dB. Impedance: Test Ports 1&2: 75 ohm, all other RF Ports: 50 ohm. Connectors: 1&2: 75 ohm Type N Female, All Other RF Ports: 50 ohm Type N Female, DC Bias Inputs: 50 ohm BNC Female. DC Bias Input Range: ±30 Vdc, ±200 mA, some degradtion in RF Specifications from 500 kHz to 100 MHz; 500 mA maximum. Damage level: 1 watt (+30 dBm) CW.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8503B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your Keysight (Agilent) 8503B CALIBRATION and/or Keysight (Agilent) 8503B 75 Ohm S-parameter Test Set REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: