Keysight (Agilent) 85052B REPAIR and Keysight (Agilent) 85052B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 85052B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 85052B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration / Verification Kits? Shop for Comparable Products on our   new Calibration / Verification Kits page

 
   Keysight (Agilent) 85052B   Description / Specification:    
Keysight (Agilent) 85052B 26.5 GHz 3.5 mm Calibration Kit

The Agilent 85052B 3.5 mm calibration kit is used to calibrate Agilent network analyzers up to 26.5 GHz for measurements of components with 3.5-mm connectors. The 85052B calibration kit includes the following items: User’s and service guide. Offset opens and shorts, broadband loads and sliding load terminations. 3.5 mm gage set. Three 3.5 mm adapters. 5/16 in, 90 N-cm (8 in-lb) torque wrench. Open-end wrench. Two data disks that contain the calibration definitions of the devices in the calibration kit. The broadband loads are metrology-grade terminations that have been optimized for performance up to 26.5 GHz. The rugged internal structure provides for highly repeatable connections. A distributed resistive element on sapphire provides excellent stability and return loss. The offset opens and shorts are built from parts that are machined to the current state-of-the-art in precision machining. The offset short’s inner conductors have a one-piece construction, common with the shorting plane. The construction provides for extremely repeatable connections. The offset opens have inner conductors that are supported by a strong, low-dielectric constant plastic to minimize compensation values.



 

Standard Calibration $805.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 85052B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your Keysight (Agilent) 85052B REPAIR and/or Keysight (Agilent) 85052B 26.5 GHz 3.5 mm Calibration Kit CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: