Keysight (Agilent) 85081B REPAIR and Keysight (Agilent) 85081B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 85081B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 85081B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) 85081B   Description / Specification:    
Keysight (Agilent) 85081B 1 GHz High-Impedance Input Module

The HP 85081B Input Module (100 kHz to 1 GHz, high impedance probe inputs) is for use with a 8508A and HP 70138A vector voltmeter. It provides the accuracy and dynamic range to make measurements on active and passive components. Module Specifications with a 8508A or 70138A. Frequency Range: 100 kHz to 1 GHz. Maximum Input: 2 V peak ac, ± 50 Vdc. A (ref) Channel Minimum: 10 mV, 100 kHz to 300 kHz; 1 mV, 300 kHz to 3 MHz; 300 uV, 3 MHz to 1 GHz. B Channel Noise Level: 10 uV. Input Crosstalk: > 100 dB, 1 MHz to 500 MHz > 80 dB, 500 MHz to 1 GHz. Magnitude Accuracy Absolute accuracy (A, B 100 mV, 15° to 30° C): + 1/ -1.5 dB, 100 kHz to 300 kHz, to ± 1 dB, 300 MHz to 1 GHz. Magnitude Accuracy Ratio accuracy (A, B 100 mV, 15° to 30° C): ± 1 dB, 100 kHz to 300 kHz, to ± .6 dB, 300 MHz to 1 GHz. Magnitude Accuracy Phase accuracy (A, B 100 mV, 15° to 30° C): ± 4, 300 kHz to 1 MHz, to ±6, 300 MHz to 1 GHz. Search and Lock Time: Lockup (within one range): 40 ms, frequencies up to 3 MHz; 20 ms, frequencies greater than 3 MHz.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 85081B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 85081B REPAIR and/or Keysight (Agilent) 85081B 1 GHz High-Impedance Input Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: