Keysight (Agilent) 8593A REPAIR and Keysight (Agilent) 8593A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8593A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8593A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) 8593A   Description / Specification:    
Keysight (Agilent) 8593A 22 GHz High Performance RF Spectrum Analyzer

The HP 8593A High performance portable Spectrum Analyzer offers frequency accuracy and a wide range of options for applications that demand higher performance. The HP 8593A has a frequency range of9 kHz to 22 GHz or 26.5 GHz with option 026, an internal preselector, and an amplitude range of -114 to + 30 dBm. (For general export, the HP 8593A option 1BH does not tune above 18 GHz nor span greater than 2.3 GHz.) It has standard 7.5 ppm frequency accuracy that can be improved with an optional precision frequency reference to marker count accuracy of ± 230 Hz at 1 GHz or ± 2.3 kHz at 18 GHz. The HP 8593A comes with a built-in memory card reader that enables you to load HP's custom measurement personalities and measurement data into the spectrum analyzer using 32-Kbyte memory cards. A catalog function allows you to determine the exact content of information stored on your memory cards or within internal memory. Specifications. Frequency range: 9 kHz to 22 GHz, 26.5 GHz (Opt 026). Span range: 0 Hz (zero span), [10 x N] kHz to 19.25 GHz. Span accuracy: Span <= 10 MHz: ±2% of span, Span > 10 MHz: ±3%. Sweeptime Range: Span = 0 Hz or > 10 kHz: 20 ms to 100 s. Sweeptime Accuracy: 20 ms to 100 s: ±3%. Amplitude range: -114 to +30 dBm. Displayed average noise level: <= -114 to <= -92 dBm. Resolution bandwidth: 1 kHz to 3 MHz, ±20%; 9 kHz and 120 kHz (6 dB). Video bandwidth range: 30 Hz to 1 MHz. Built-in memory card reader. Options. 004: Precision Frequency Reference. 010: 50 ohm Built-in Tracking Generator. 021: HP-IB Interface. 023: RS-232 Interface. 026: 26.5 GHz Frequency Extension. 101: Fast Time Domain Sweeps. 102: AM/FM Demodulator and TV Sync Trigger. 103: Quasi-Peak Detector/AM-FM Demodulator. 105: Time-gated Spectrum Analysis.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8593A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) 8593A REPAIR and/or Keysight (Agilent) 8593A 22 GHz High Performance RF Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: