Keysight (Agilent) 86102A REPAIR and Keysight (Agilent) 86102A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86102A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86102A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   Keysight (Agilent) 86102A   Description / Specification:    
Keysight (Agilent) 86102A 10 GHz Optical / 20 GHz Electrical Plug-in Module

The Agilent 86102A is a 10 GHz Optical / 20 GHz Electrical Plug-in module for 86100 Infiniium DCA. It supports waveform compliance testing of short wavelength signals with up to 10 GHz of optical bandwidth. Each module also has an electrical channel with 20 GHz of bandwidth. Filtered data rates; Option 201: 2125 Mb/s and 3.1875 Gb/s. Option 202: 2488/2500 Mb/s and 3.125 Gb/s. Option 203: 2.72 Gb/s and 3.32 Gb/s. Wavelength range (nm): 750 to 860. Fiber input (um): 62.5. Mask test sensitivity (dBm): -13.5.



 

Standard Calibration $950.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86102A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 86102A REPAIR and/or Keysight (Agilent) 86102A 10 GHz Optical / 20 GHz Electrical Plug-in Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: