Keysight (Agilent) 86108A CALIBRATION and Keysight (Agilent) 86108A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86108A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   Keysight (Agilent) 86108A   Description / Specification:    
Keysight (Agilent) 86108A Precision Waveform Analyzer Plug-in Module

The Agilent 86108A Precision Waveform Analyzer is a plug-in module used with the 86100C Infiniium DCA-J Digital Communications Analyzer that provides an ideal solution to this accuracy problem. The 86108A has a bandwidth in excess of 33 GHz, channel noise of less than 300 uV, and residual jitter at an astounding level of under 100 femtoseconds (60 fs typical). Bandwidth: 16 GHz and < 32 GHz, (35 GHz). Transition time (10% to 90% calculated from Tr = 0.35/BW): 10 ps. RMS noise (Characteristic): 240 uV (16 GHz) 420 uV (32 GHz). DC accuracy (single marker): ±0.7% of full scale, ±2 mV ±1.5% (16 GHz), (±3% 32 GHz) of (reading-channel offset). CW offset range (referenced from center of screen): ±500 mV. Input dynamic range (relative to channel offset): ±400 mV. Maximum input signal: ±2 V (+16 dBm). Refl ections (for 30 ps rise time): 5%. Clock Recovery; Data rates input range: Continuous tuning 0.05 to 13.5 Gb/s. Clock frequency input range: Continuous tuning 0.025 to 6.75 GHz. Minimum input level to aquire lock: 175 m Vpp. Minimum input level to aquire lock and achieve jitter specifications: 125 m Vpp. Clock recovery adjustable loop bandwidth range (user selectable): 0.015 to 10 MHz. Loop bandwidth accuracy: ±30%. Aquisition range: ±5000 ppm. Residual spread spectrum: -72 ±3 dB @ 33 kHz. Internal frequency counter accuracy: ±10 ppm.



 

Standard Calibration $1,390.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86108A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 86108A CALIBRATION and/or Keysight (Agilent) 86108A Precision Waveform Analyzer Plug-in Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: