Keysight (Agilent) 86116B REPAIR and Keysight (Agilent) 86116B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86116B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86116B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   Keysight (Agilent) 86116B   Description / Specification:    
Keysight (Agilent) 86116B 65 GHz Optical / 80 GHz Electrical Plug-in Module

The Agilent 86116B is a plug-in module for a 86100 Infiniium DCA Module. It incorporates two measurement channels, one optical and one electrical. Electrical Channel Bandwidth: 80, 55 and 30 GHz. DC Accuracy (single marker): ±0.4% of full scale ±3 mV ±2% of (reading- channel offset), ±2% of offset (all bandwidths). Wavelength Range: 1480-1620 nm, (9/125 µm, user selectable connector). Optical Channel Unfiltered Bandwidth: 65 GHz (best pulse fidelity). Maximum Input Power (non-destruct average) 10 mW (+10 dBm).



 

Standard Calibration $1,390.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86116B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 86116B REPAIR and/or Keysight (Agilent) 86116B 65 GHz Optical / 80 GHz Electrical Plug-in Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: