Keysight (Agilent) 86120A REPAIR and Keysight (Agilent) 86120A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86120A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86120A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Wavelength Meter?
Shop for Comparable Products on our
 used Wavelength Meter page

 
   Keysight (Agilent) 86120A   Description / Specification:    
Keysight (Agilent) 86120A Optical Multi-Wavelength Meter

Multi-Wavelength Meter. Wavelength : 700 nm to 1650 nm. Absolute accuracy (lines separated by >=30 GHz): ±3 ppm (±0.005 nm at 1550 nm and ±0.004 nm at 1310 nm). Differential accuracy (characteristic): ±2 ppm. Minimum resolvable separation (characteristic): 20 GHz (0.16 nm at 1550 nm, 0.11 nm at 1300 nm). Display resolution: 0.001 nm. Amplitude Linearity, 1200 nm to 1600 nm, lines above -20 dBm: ±0.3 dB. Flatness, ±30 nm from any wavelength: 1200-1600 nm (characteristic): ±0.2 dB. Display resolution: 0.01 dB. Maximum safe input level (sum of all lines): +18 dBm. Measure up to 100 laser lines simultaneously.


Repair Services / Additional Information.


Common 86120 Repairable Errors
We have repaired over 1000 86120's with a success rate of over 99% and with most replacement parts in stock. Our typical repair time is less than 5 business days.
The following is a list of common repairable errors (In order of prevalence).
E14 (ERROR 14) "DATA ACQUISITION PROBLEM" or "DATA ACQUISITION ERROR"
We repair the E14 error using NEW, original manufacturer parts, which comes with a one year warranty. We don't use refurbished or cheap generic parts.
E4 (ERROR 4) "MOTOR INDEX PULSE NOT FOUND"
E7 (ERROR 7) "MOTOR NOT SETTLED"  
E34 (ERROR 34) "BATTERY FAILED"


 

Standard Calibration $530.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86120A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Broadband Source (BBS)
A Broadband Source is a spectrally large source that emits a signal which contains a continuous range of frequencies with a broad optical bandwidth (usually 100 nm or more). Sometimes called a white light source, there are two different meanings of this term. Visible white light and a source which does not necessarily emit in the visible spectral region.

Coherence
Coherence is the pattern and or relationships of waves due to phase properties.

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Power Flatness Over Modulation
When changing the wavelength and modulation frequency, and measuring the differences between actual and displayed power levels (in dB), the power flatness is ± half the span between the maximum and the minimum value of all differences.

Singlemode fiber
Singlemode Fiber has a small core, only about 9 microns, and is used for telephony and CATV with laser sources at 1300 and 1550 nm. It can go very long distances at very high speeds. Both multimode and singlemode fiber have an outside diameter of 125 microns - about 5 thousandths of an inch - just slightly larger than a human hair.


Please contact us for your Keysight (Agilent) 86120A REPAIR and/or Keysight (Agilent) 86120A Optical Multi-Wavelength Meter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: