Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8648D. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8648D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 8648D   Description / Specification:    
Keysight (Agilent) 8648D 4000 MHz Synthesized Signal Generator

The HP 8648D 4000 MHz synthesized signal generator delivers solid performance and reliability. This signal generator provides the features and performance needed for semi-automated receiver testing and for use in a variety of general-purpose applications over a 9 kHz to 4000 MHz frequency range. The HP 8648D provides ±1 dB absolute amplitude accuracy up to 2.5 GHz. It offers ultra stable dc FM, with ±500 Hz carrier frequency accuracy below frequencies of 1001 MHz, and low RF leakage. Applications such as receiver tuning and alignment benefit from the simple user interface. These signal generators are so easy to learn and use that experienced operators are no longer required. With 300 full storage registers and ten user-definable sequences, the signal generator easily adapts to any test procedure. Once setups are stored in registers, operators can quickly sequence through them, either from the front panel or through a remote keypad (HP 83300A). In addition, the HP 83301A memory interface provides the means to transfer register information from one HP 8647/48 to another. Specifications. Frequency: 9 kHz to 4000 MHz. Resolution: 0.001 Hz (Display: 10 Hz). Switching Speed (typical): <1001 MHz: < 75 ms; >=1001 MHz: < 100 ms. Accuracy (after one hour warm-up and within one year calibration): Typically ± 3 x 10^–6 x carrier frequency in Hz, ± 0.15 x 10^–6 x carrier frequency in Hz for Option 1E5 (typically ± 0.072 x 10^–6 x fc). Internal Reference Oscillator Accuracy and Stability (calibration adjustment dependent; after one hour warm-up and within one year of calibration), ± aging rate ± temperature effects ± line voltage effects. Internal Reference Oscillator Output: 10 MHz, typically > 0.5 Vrms into 50 ohm. External Reference Oscillator Input: Accepts 2, 5, 10 MHz ±5 ppm and a level range of 0.5 V to 2 Vrms into 50 ohm. Harmonics (output <= 4 dBm): < –30 dBc. Subharmonics (output <= +4 dBm) < 1001 MHz: –60 dBc; >= 1001 MHz: –50 dBc: > 3200 MHz: –40 dBc. Output Range: <= 2000 MHz: +13 to –136 dBm: > 2500 MHz: +10 to –136 dBm. Options. Opt 1EA High Power. Opt 1E6 Pulse. Opt 1E2 Modulation Generator. Opt 1E5 High-Stability Timebase.



 

Standard Calibration $650.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8648D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 8648D REPAIR and/or Keysight (Agilent) 8648D 4000 MHz Synthesized Signal Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: