Keysight (Agilent) 8672A REPAIR and Keysight (Agilent) 8672A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8672A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8672A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 8672A   Description / Specification:    
Keysight (Agilent) 8672A 18 GHz Synthesized RF Signal Generator

The HP 8672A Synthesized Signal Generator delivers precise microwave signals over the 2.0 to 18.0 GHz frequency range. It features calibrated and leveled output power, AM/ FM modulation capability, and full HP-IB programmability. The HP 8672A delivers exceptionally flat power across the full frequency range. For receiver sensitivity measurements, power is internally (or externally) leveled and calibrated to - 120 dBm. Specifications. Frequency range: 2.0-18.0 GHz (18 .6 GHz overrange). Time base: internal 10 MHz (< 5 X 10^-10 / day aging rate) or external 5 or 10 MHz. Frequency switching time: < 20 ms to be within specified resolution, all bands. Harmonics (up to maximum frequency, output level meter readings < 0 dB on 0 dBm range and below): <-25 dBc. Sub-harmonics and multiples thereof: <-25 dBc, Bands 1-3. Output level (+ 15°C to + 35°C): +8 to -120 dBm. Amplitude Modulation Rates (3 dB BW, 30% depth): 20 Hz - 100 kHz. Sensitivity: 30%/V, 100%/V ranges. Max. input 1 V peak into 600 ohm. Options. Option 001: Delete RF output attenuator. Option 002: Delete reference oscillator. Option 003: Operation at 50/60/400 Hz line. Option 004: Rear panel RF output. Option 005: Rear panel RF output without RF attenuator.



 

Standard Calibration $650.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8672A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your Keysight (Agilent) 8672A REPAIR and/or Keysight (Agilent) 8672A 18 GHz Synthesized RF Signal Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: