Keysight (Agilent) 8673D REPAIR and Keysight (Agilent) 8673D CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8673D. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8673D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 8673D   Description / Specification:    
Keysight (Agilent) 8673D 26 GHz Synthesized Signal Generator

The HP 8673D Synthesized Signal Generator is a full performance synthesizer designed to generate precise microwave signals over the 50 MHz to 26 GHz frequency range. It includes an internal tracking YIG-filter to further reduce unwanted harmonic, subharmonic, and non harmonic spurious signals above 1.2 GHz to <-60dBc. The HP 8673D delivers exceptionally flat power output across the full frequency ranges. For receiver sensitivity measurements, power is internally (or externally) leveled to -100 dBm. It features an internal pulse modulator that provides high-quality pulse modulation over the entire 50 MHz - 26 GHz range. Since the modulation is done before the frequency multiplication, the peak pulsed power can be leveled and calibrated to within typically +1.5/ -1.0 dBm of the set level referenced to CW. External TTL level pulse rates up to 1 MHz and pulse widths as narrow as 100 ns. Specifications. Frequency Range: 0.05-26.0 GHz (0.01 - 26.5 GHz in overrange). Frequency Bands: Band 0; 0.05 - 2.0 GHz, Band 1; 2.0 - 6.6 GHz, Band 2; 6.6 - 12.3 GHz, Band 3; 12.3 - 18.6 GHz, Band 4; 18.6 - 26.0 GHz. Frequency Resolution: 1 kHz Band 0 and 1, 3 kHz Band 3, 2 kHz Band 2, 4 kHz Band 4. Time base: internal 10 MHz (<5 x 10 ^- 10 / day aging rate) or external 5 or 10 MHz. Output level: +11 to -100 dBm @ .05 - 2.0 GHz. Option 001: Delete RF output attenuator. Option 002: Delete reference oscillator. Option 004: Rear panel RF output. Option 006: Chassis slide kit.



 

Standard Calibration $650.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8673D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) 8673D REPAIR and/or Keysight (Agilent) 8673D 26 GHz Synthesized Signal Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: