Keysight (Agilent) 8711A REPAIR and Keysight (Agilent) 8711A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8711A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8711A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8711A   Description / Specification:    
Keysight (Agilent) 8711A RF Network Analyzer

The HP 8711A characterizes the transmission/reflection frequency response or measure the insertion loss, gain, return loss, conversion loss, power. or SWR of a variety of RF components. Integrated synthesized source and transmission/ reflection test set enable the complete swept frequency characterization of RF components with a single connection. The internal synthesized source is a fast (50 ms/sweep) and stable (l Hz resolution) stimulus for testing narrowband devices. Source Characteristics; Frequency Range: 300 kHz to 1300 MHz. Frequency Resolution : 1 Hz. Frequency Accuracy: < 5 ppm. Power range: 0 to 16 dBm, with attenuator - 60 to 13 dBm (75 ohm reduces output by 3 dB). Resolution Port flatness: + / -1.0 dB, w/attenuator + /- 2.0 dB, w/meter correction + /- 0.3 dB. Harmonics: < -30 dBc. Spurious: < 30 dBc. Phase noise: < 67 dBc/Hz, at 10 kHz (typical). Receiver Characteristics; Frequency range Narrowband: 300 kHz to 1300 MHz, Broadband: 10 MHz to 1300 MHz. Maximum input Narrowband: 10 dBm, 0.8 dB compression, Broadband: 16 dBm, 0.5 dB compression. Test port match: 20 dB. System directivity: 40 dB. Option 1EC: 75 System Impedance. Option 1E1: 60 dB Attenuator.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8711A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your Keysight (Agilent) 8711A REPAIR and/or Keysight (Agilent) 8711A RF Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: