Keysight (Agilent) 8753A REPAIR and Keysight (Agilent) 8753A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8753A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8753A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8753A   Description / Specification:    
Keysight (Agilent) 8753A 3 GHz Network Analyzer

The HP 8753A 3 GHz Network Analyzer provides excellent RF network measurements for lab and production test areas. When combined with a test set, it yields a complete solution for characterizing the linear behavior of either active or passive networks, devices, or components from 300 kHz to 3 GHz. With two independent display channels available, you can simultaneously measure and display the reflection and transmission characteristics of the device under test. Specifications. Frequency Range: 300 kHz to 3 Ghz. Frequency Resolution: 1 Hz. Frequency Accuracy (25 C): ±10 ppm. Source Output Characteristics. Power Range: -5 to +20 dBm. Power Accuracy (50 MHz, +10 dBm): ±0.5 dB. Power Linearity (relative to +10 dBm, 25 ±5 C): -5 to + 15 dBm: ±0.2 dB; + 15 to +20 dBm: ±0.5 dB. Impedance 50 ohm. Harmonics: = -25 dBc (20 dBm output level); typically < -50 dBc (0 dBm output level). Receiver. Frequency Range: 300 kHz to 3 GHz. Inputs: A, B 100 dB dynamic range. Sensitivity (noise level): 3 kHz BW: -90 dBm; 10 Hz BW: -100 dBm (typically -110 dBm). Maximum Input Level: 0 dBm. Impedance: 50 ohm. Input Crosstalk: 300 kHz to 1 GHz: -100 dB; 1 GHz to 3 GHz: -90 dB. Dynamic Accuracy: ±0.05 dB, ±0.5 deg over a 50 dB input range. Options. 010, Time Domain Capability.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8753A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Standing Wave Ratio (SWR)
Standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).


Please contact us for your Keysight (Agilent) 8753A REPAIR and/or Keysight (Agilent) 8753A 3 GHz Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: