Keysight (Agilent) 8904A REPAIR and Keysight (Agilent) 8904A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8904A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8904A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 8904A   Description / Specification:    
Keysight (Agilent) 8904A 600 kHz Multifunction Synthesizer

The Agilent 8904A Multifunction Synthesizer uses VLSIC technology to create complex signals from six fundamental waveforms. The standard 8904A digitally synthesizes precise sine, square, triangle, ramp, white noise, and dc waveforms and routes these signals to a single output. Option 001 adds three more identical internal synthesizers (channels) which can either modulate the first synthesizer or be summed to the output. Frequency, amplitude, waveform, phase, and destination can be independently set for each synthesizer. Available modulation types for channel A include AM, FM, F M, DSBSC, and pulse modulation. Specifications. Frequency Range Sine wave: 0 Hz to 600 kHz. Frequency Range Square, triangle, ramp: 0 Hz to 50 kHz. Resolution: 0.1 Hz. Accuracy: Internal 10 MHz timebase: ±50 ppm. AC amplitude (sinewave) Range: 0 to 10 Vp-p into a 50 ohm load. Resolution: 3 1/2 digits. Phase (sine wave) Range: 0 to 359.9°. Resolution: 0.1° or 0.001 radians. DC Amplitude Range: 0 to ±10 V open circuit. Resolution: Three and a half digits. Accuracy: ±20 mV or ±2.1%, whichever is greater. Switching Speed (via GPIB): Typically <25 ms. Options. Option 001: Add three internal channels, channel A modulation, channel summation, and channel A sequence capability. Option 002: Add second internal synthesizer and 50 ohm output. Option 003: Add fast hop and digital modulation capability. Option 004: Move outputs to rear panel (Not available with either Option 005 or 006). Option 005: Add unit to unit phase synchronization capability. Option 006: Changes output 1 from a 50 ohm output to a transformer coupled, 600 ohm balanced output.



 

Standard Calibration $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8904A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) 8904A REPAIR and/or Keysight (Agilent) 8904A 600 kHz Multifunction Synthesizer CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: