A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO6102A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO6102A (DS06102A)   Description / Specification:    
Keysight (Agilent) DSO6102A 2 Ch 1 GHz InfiniiVision Oscilloscope

The Agilent DSO6102A InfiniiVision 1 GHz, 2 analog channel oscilloscope is equipped with a 6.3” XGA LCD display, comes in a whisper-quiet package that weighs only 11 pounds. The InfiniiVision 6000 Series shows jitter, infrequent events, and subtle signal detail that other scopes miss. Turn knobs and the instrument responds instantly and effortlessly. InfiniiVision scopes incorporate acquisition memory, waveform processing, and display memory in an advanced 0.13 µ ASIC. This patented 3rd generation technology, known as MegaZoom III, delivers up to 100,000 waveforms (acquisitions) per second with responsive deep memory always available. Specifications. Bandwidth: 1 GHz. Sample rate: 4 GSa/sec half channel, 2 GSa/sec each channel Equivalent-time sample rate: 400 GSa/s (when real-time mode is turned off). Maximum memory depth 2 channels: 8 Mpts. Input channels: 2 analog. Vertical resolution. 8 bits. Peak detection: 250-ps peak detect. Averaging Selectable from: 2, 4, 8, 16, 32, 64 ... to 65536. High resolution mode: Average mode with avg = 1, 12 bits of resolution when >=10 µs/div @ 4 GSa/s or >=20 µs/div @ 2 GSa/s. Vertical system scope channels; Scope channels: Ch 1 and 2 simultaneous acquisition. Bandwidth (–3dB): DC to 1 GHz. Calculated rise time (=0.35/bandwidth): 350 psec. Single-shot bandwidth: 1 GHz. Range: 2 mV/div to 5 V/div (1 Mohm), 2 mV/div to 1 V/div (50 ohm). Maximum input: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk. Horizontal; Range: 500 psec/div to 50 sec/div. Resolution: 2.5 psec. Time scale accuracy: <= ± (15 + 2*(instrument age in years)) ppm.



 

Standard Calibration $565.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO6102A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) DSO6102A CALIBRATION and/or Keysight (Agilent) DSO6102A 2 Ch 1 GHz InfiniiVision Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: