Keysight (Agilent) E3611A REPAIR and Keysight (Agilent) E3611A CALIBRATION

The Keysight (Agilent) E3611A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E3611A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E3611A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) E3611A   Description / Specification:    
Keysight (Agilent) E3611A Single-output Dual Range CV/CC DC Power Supply

The Agilent E3611A Single-output Dual Range CV/CC Power Supply is designed for general laboratory use. The constant-voltage, constant-current output allows operation as either a voltage source or current source. The changeover occurs automatically, based on the load. This feature also provides an adjustable current limit, allowing you to set the safest current limit level for a particular DUT. Also, a CC-set button lets you set the current limit without having to short the output. The Agilent E3611A has two ranges, allowing more current at a lower voltage. For a higher-output voltage, supplies can be connected in series. Either the positive or negative terminal can be connected to ground, providing a positive or negative voltage output. Either terminal can also be floated up to 240 V from ground. Dual digital meters monitor current and voltage simultaneously. Adjustments are made with the 10-turn voltage control and the 10-turn current control. Output Range 1: 0 to 20 V, 0 to 1.5 A (30 W). Output Range 2: 0 to 35 V, 0 to 0.85 A (30 W). Load and line regulation: 0.01% +2 mV. Ripple and noise: rms 200 µV, peak-to-peak 2 mV. Resolution Voltage: 100 mV. Resolution Current: 10 mA.



 

Standard Calibration $145.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E3611A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) E3611A REPAIR and/or Keysight (Agilent) E3611A Single-output Dual Range CV/CC DC Power Supply CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: