Keysight (Agilent) E3632A REPAIR and Keysight (Agilent) E3632A CALIBRATION

The Keysight (Agilent) E3632A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E3632A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E3632A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) E3632A   Description / Specification:    
Keysight (Agilent) E3632A Single Output Dual-range DC Power Supply

The HP E3632A is a single output, dual range programmable dc power supplies designed to deliver reliable and high quality operation. 0.01% load and line regulation keep the output steady. The linear supply specifies both normal-mode voltage noise and common-mode current noise. The low normal-mode specification assures clean power for precision circuitry and the low common-mode current provides isolation from power line current injection. Both voltage and current can be monitored simultaneously for output from the front panel on an easy-to-read vacuum fluorescent display. A knob allows you to set the output at the resolution you need for the most exacting adjustments, quickly and easily. Store and recall key enables you to save and recall up to three frequently-used states. The output on/off button enables/disables the output. All the outputs are isolated from the chassis ground and from the remote interface. Specifications. DC Output Low Range/High Range: 0 to 15 V, 7A / 0 to 30 V, 4 A. Load and line regulation Voltage: < 0.01% + 2 mV. Load and line regulation Current: < 0.01% + 250 µA. Ripple and noise (20 Hz to 20 MHz) Normal-mode: < 350 µV rms / 2 mV p-p (Voltage), < 2 mA rms (Current). Ripple and noise (20 Hz to 20 MHz) Common-mode Current: <1.5 µA rms. Programming accuracy (25° C ±5° C): 0.05% + 10 mV (Voltage), 0.2% +10 mA (Current). Readback accuracy (25° C ±5° C): 0.05% + 5 mV (Voltage), 0.15% +5 mA (Current). Resolution Program/readback: 1 mV, 0.5 mA / 0.5 mV, 0.1 mA. Resolution Meter: 1 mV / 1 mA. Transient Response Time: 50 µsec for output to recover to within 15 mV following a change in output current from full load to half load or vice versa. GPIB/RS-232 standard.



 

Standard Calibration $145.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E3632A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) E3632A REPAIR and/or Keysight (Agilent) E3632A Single Output Dual-range DC Power Supply CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: