Keysight (Agilent) E3634A CALIBRATION and Keysight (Agilent) E3634A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E3634A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) E3634A   Description / Specification:    
Keysight (Agilent) E3634A Single Output Dual-range DC Power Supply

The Agilent E3634A is a single output, dual range programmable dc power supply designed to deliver reliable and high quality operation. It has 0.01% load and line regulation keep the output steady. The linear supply specifies both normal-mode voltage noise and common-mode current noise. The low normal-mode specification assures clean power for precision circuitry and the low common-mode current provides isolation from power line current injection. Both voltage and current can be monitored simultaneously for output from the front panel on an easy-to-read vacuum fluorescent display. A knob allows you to set the output at the resolution you need for the most exacting adjustments, quickly and easily. Store and recall key enables you to save and recall up to three frequently-used states. The output on/off button enables/disables the output. All the outputs are isolated from the chassis ground and from the remote interface. Specifications. DC Outputs: 0 to 25 V / 7A or 0 to 50 V / 4 A. Power (max): 200 W. Load and Line Regulation (Voltage / Current): <0.01% + 2 mV / < 0.01% + 250 uA. Ripple and Noise (20 Hz to 20 MHz); Normal-Mode Voltage: <500 µVrms / 3 mVpp. Normal-Mode Current: < 2 mArms. Common-Mode Current: < 1.5 uArms. Programming Accuracy (Voltage / Current): 0.05% + 10 mV / 0.2% + 10 mA. Readback Accuracy (Voltage / Current): 0.05% + 5 mV / 0.15% + 5 mA. Resolution Program (Voltage / Current): 3 mV / 0.5 mA. Resolution Readback (Voltage / Current): 1.5 mV / 0.5 mA. Resolution Meter (Voltage / Current): 10 mV / 1 mA (<10 A), 10 mA (>= 10A). Transient response time: <50 us for output to recover within 15 mV following a change in output current from full load to half load or vice versa.



 

Standard Calibration $145.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E3634A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) E3634A CALIBRATION and/or Keysight (Agilent) E3634A Single Output Dual-range DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: