Keysight (Agilent) E4418A REPAIR and Keysight (Agilent) E4418A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E4418A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E4418A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Meter?
Shop for Comparable Products on our
 used RF Power Meter page

 
   Keysight (Agilent) E4418A (EPM-441A)   Description / Specification:    
Keysight (Agilent) E4418A Single-Channel EPM-Series Power Meter

The HP EPM-441A is a single-channel, programmable power meter. It is fully compatible with the HP 8480 series of power sensors and the ECP series of power sensors. Depending upon which sensor is used, the HP EPM 441A can measure from –70 dBm to +44 dBm at frequencies from 100 kHz to 110 GHz. Designed for bench and automatic test equipment (ATE) use, the EPM-441A makes fast (up to 200 readings per second with ECP series sensors), accurate and repeatable power measurements. The EPM-441A power meter has a high-resolution LCD display with LED backlighting and contrast control. This allows users to see the power readings from a distance, at a wide viewing angle and in a variety of lighting conditions. The user interface is easy to learn and use, with hardkeys for the most frequently used functions, and softkey menus to simplify instrument configuration for different applications. Ten instrument configurations can be saved and recalled, reducing the need to repeat setup sequences. Because the EPM-441A power meter is designed to be code-compatible with the previous-generation HP 437B power meter, a user’s investment in automatic-test procedures, software generation and verification is protected. Front and rear panel bumpers protect the EPM-441A from everyday knocks. The meter weighs only 4 kg (9lbs), and a bail handle makes it easy to carry. Specifications. Frequency Range: 100 kHz to 50 GHz and 75 GHz to 110 GHz, sensor dependent. Power Range: –70 dBm to +44 dBm (100 pW to 25 W), sensor dependent. Power Sensors: Compatible with all HP 8480 series and HP ECP series sensors. Display Units: Watts or dBm (Absolute), Percent or dB (Relative). Display Resolution: Selectable resolution of 1.0, 0.1, 0.01, and 0.001 dB in log mode, or 1 to 4 digits in linear mode. Default Resolution: 0.01 dB in log mode, 3 digits in linear mode. Instrumentation Accuracy Absolute: ± 0.02 dB (log) or ± 0.5% (linear). Add the corresponding power sensor linearity percentage. Instrumentation Accuracy Relative: ± 0.04 dB (log) or ± 1.0% (linear). Add the corresponding power sensor linearity percentage. Opt 002, Supplies rear-panel sensor input (power reference calibrator is on front panel). Opt 003, Supplies rear-panel sensor input (power reference calibrator is on rear panel). Opt 004, Deletes the HP 11730A sensor cable.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E4418A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) E4418A REPAIR and/or Keysight (Agilent) E4418A Single-Channel EPM-Series Power Meter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: