Keysight (Agilent) E4430B REPAIR and Keysight (Agilent) E4430B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E4430B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E4430B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) E4430B   Description / Specification:    
Keysight (Agilent) E4430B 1000 MHz ESG-D Digital RF Signal Generator

The Agilent E4430B 1000 MHz ESG-D RF signal generator provides a wide range of digital modulation capabilities, in addition to a comprehensive feature set and excellent analog performance. The E4430B provides excellent modulation accuracy and stability, as well as unprecedented level accuracy. Use the analog I and Q inputs to generate complex modulation formats required for the development and testing of RF digital communications systems. A built-in quadrature modulator processes the I and Q input signals to provide superior modulation accuracy and stability over 10 MHz (1dB) baseband bandwidth. Superior level accuracy of ±0.5 dB (above –127 dBm, fc <2 GHz) provides unmatched specified performance and minimizes test uncertainty. Even with digital modulation turned on, level accuracy is better than ±1.1 dB. This unprecedented performance ensures precise measurement of even the most sensitive analog or digital receivers. Specifications. Frequency Range: 250 kHz to 1000 MHz. Resolution: 0.01 Hz. Frequency Accuracy: fc x timebase accuracy. Frequency switching speed for Modulation on: <90 ms. Sweep Modes: Step: frequency and power, and arbitrary list. Dwell Time: 1 ms to 60 sec. Number of points: 2 to 401. 20 MHz RF bandwidth for I and Q. Step sweep (frequency, power, and list). Wideband AM, FM, and phase modulation. Options. Opt 1E5, Add high-stability timebase. Opt UNA, Alternate time slot level control (for Option UN8). Opt UNB, High power with mechanical attenuator. Hardware Options. Opt UN7, Internal Bit-Error-Rate Analyzer. Opt UN8, Real-Time I/Q Baseband Generator. Opt UN9, Add 7M RAM to Opt UN8. Opt UND, Internal Dual Arbitrary Waveform Generator. Firmware Options. Opt UN5, Multicarrier, multichannel cdmaOne Personality for Option UND. Opt 100, Multichannel, Multicarrier 3GPP W-CDMA Personality for Option UND. Opt 101, Multichannel, Multicarrier cdma2000 Personality for Option UND. Opt 200, Real-Time 3GPP W-CDMA Personality for Option UN8/UN9. Opt 201, Real-Time cdma2000 Personality for Option UN8. Opt 202, Real-Time EDGE Personality for Option UN8.



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E4430B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) E4430B REPAIR and/or Keysight (Agilent) E4430B 1000 MHz ESG-D Digital RF Signal Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: