Keysight (Agilent) E4436B REPAIR and Keysight (Agilent) E4436B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E4436B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E4436B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) E4436B   Description / Specification:    
Keysight (Agilent) E4436B 3000 MHz ESG-DP Digital RF Signal Generator

The Agilent E4436B 3000 MHz ESG-DP RF signal generator provides a wide range of digital modulation capabilities, in addition to a comprehensive feature set and excellent analog performance. The E4436B provides outstanding phase-noise performance. It also provides excellent modulation accuracy and stability, as well as unprecedented level accuracy. Use the analog I and Q inputs to generate complex modulation formats required for the development and testing of RF digital communications systems. A built-in quadrature modulator processes the I and Q input signals to provide superior modulation accuracy and stability over 10 MHz (1dB) baseband bandwidth. Superior level accuracy of ±0.5 dB (above –127 dBm, fc <2 GHz) and ±0.9 dB (fc >2 GHz) provides unmatched specified performance and minimizes test uncertainty. Even with digital modulation turned on, level accuracy is better than ±1.1 dB. This unprecedented performance ensures precise measurement of even the most sensitive analog or digital receivers. Specifications. Frequency Range: 250 kHz – 3000 MHz. Resolution: 0.01 Hz. Frequency Accuracy: fc x timebase accuracy. Frequency switching speed for Modulation on: <100 ms. Sweep Modes: Step: frequency and power, and arbitrary list. Dwell Time: 1 ms to 60 sec. Number of points: 2 to 401. 20 MHz RF bandwidth for I and Q. Step sweep (frequency, power, and list). Wideband AM, FM, and phase modulation. Options. Opt UNA, Alternate time slot level control (for Option UN8). Opt UNB, High power with mechanical attenuator. Hardware Options. Opt UN7, Internal Bit-Error-Rate Analyzer. Opt UN8, Real-Time I/Q Baseband Generator. Opt UN9, Add 7M RAM to Opt UN8. Opt UND, Internal Dual Arbitrary Waveform Generator. Firmware Options. Opt UN5, Multicarrier, multichannel cdmaOne Personality for Option UND. Opt 100, Multichannel, Multicarrier 3GPP W-CDMA Personality for Option UND. Opt 101, Multichannel, Multicarrier cdma2000 Personality for Option UND. Opt 200, Real-Time 3GPP W-CDMA Personality for Option UN8/UN9. Opt 201, Real-Time cdma2000 Personality for Option UN8. Opt 202, Real-Time EDGE Personality for Option UN8.



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E4436B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) E4436B REPAIR and/or Keysight (Agilent) E4436B 3000 MHz ESG-DP Digital RF Signal Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: