Keysight (Agilent) E5574A REPAIR and Keysight (Agilent) E5574A CALIBRATION

The Keysight (Agilent) E5574A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E5574A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E5574A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Lightwave Measurement System?
Shop for Comparable Products on our
 used Lightwave Measurement System page or new Lightwave Measurement System page

 
   Keysight (Agilent) E5574A   Description / Specification:   Spec Sheet 
Keysight (Agilent) E5574A Optical Loss Analyzer

Optical loss Analyzer. Is a solution for the loss/gain characterization of active and passive optical components. A pigtailed optical output provides polarization dependent loss measurements with the highest performance. A selection of optical heads covers 800 to 1700 nm wavelengths and power levels between +27 and - 90 dBm. Insertion Loss/Gain and Coupling Ratio Measurement Specifications. Laser Source: Fabry-Perot laser with built-in isolator. Center wavelength, 1310 ±20 nm (Option 013), 1550 ±20 nm (Option 015), 1310/1550 ±20 nm (Option 135). Fiber Type: single-mode. 9/125 um. Display Resolution: 0.001 dB. Output Power: =10 dBm. =8 dBm typical. CW-Stability (15 min. T =const): ±0.01 dB. Backreflection Sensitivity (typical): < 0.001 dB p-p @ 4 % reflection. Maximum measurable gain (dB): upper power limit of optical head (dBm) minus source output power (dBm). Maximum measurable insertion loss (dB): output power of source (dBm) minus sensitivity of optical head (dBm).



 

Standard Calibration $475.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E5574A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chromatic Dispersion
Chromatic Dispersion is a broadening of the input signal as it travels down the length of the fiber. Chromatic Dispersion results from a variation in propagation delay with wavelength, and is affected by fiber materials and dimensions.

Detector
A Detector is a signal conversion device that converts power from one form to another, such as from optical power to electrical power

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Polarization Mode Dispersion (PMD)
Polarization mode dispersion (PMD) is a form of modal dispersion where two different polarizations of light in a waveguide, which normally travel at the same speed, travel at different speeds due to random imperfections and asymmetries, causing random spreading of optical pulses. It is he difference between the maximum and minimum values of loss typically measured in ps/km^1/2.


Please contact us for your Keysight (Agilent) E5574A REPAIR and/or Keysight (Agilent) E5574A Optical Loss Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: