ANRITSU 37347C REPAIR and ANRITSU 37347C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ANRITSU 37347C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU 37347C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU 37347C   Description / Specification:    
ANRITSU 37347C 20 GHz Lightning Vector Network Analyzer (VNA)

The Anritsu 37347C 20 GHz Lightning Vector Network Analyzer (VNA) is a high performance tool designed to make fast and accurate S-parameter measurements of active and passive devices across the 40 MHz to 20 GHz range. The network analyzer integrates a synthesized source, S-parameter test set and tuned receiver into a single compact package that is ideal for bench-top testing. High throughput measurements are achieved in each model through the use of fast, 12-term error corrected sweeps, fast GPIB data transfers and an intuitive user interface. All measurement results are displayed on a large LCD color display or on an external VGA monitor. Specifications. Frequency Range: 40 MHz to 20 GHz. Dynamic Range ("Receiver Dynamic Range" is defined as the difference between the maximum signal level at Port 2 for 0.1 dB compression and the noise floor. "System Dynamic Range" is defined as the difference between the power incident on Port 2 in a through line connection and the noise floor. High Level Noise (typical): <0.04 dB and <0.5 degrees peak-to-peak variation in a 1 kHz IF bandwidth up to 20 GHz. Max Signal Into Port 2: 30 dBm. Noise Floor: -65 dBm @ 0.04 GHz, -93 dBm @ 2 GHz, -91 dBm @ 20 GHz. Receiver Dynamic Range: 95 @ 0.04 GHz, 123 @ 2 GHz, 121 @ 20 GHz. Port 1 Power: 5 dBm. System Dynamic Range: 70 @ 0.04 GHz, 98 @ 2 GHz, 96 @ 20 GHz. Measurement Time vs. Span for 101 Data Points (typical): 40 MHz to 20 GHz, 450 ms. Number of Channels: Four independent measurement channels. Parameters: S11, S21, S22, S12, or user-defined combinations of a1, a2, b1, and b2. All measurements are made without the need to manually reverse the test device. Display LCD, Color, 8.5-inch diagonal. Options. Opt 1, Slide Rack Mounting. Opt. 1A, Rack Mounting. Opt 2A, Time Domain (Microwave Units). Opt 2B, Time Domain (RF Units). Opt 4, External SCSI-2 Hard Disk Drive Compatibility. Opt 7A/N/NF/S/K, Universal Test Port Configuration, Replaces Universal / K Connector (standard) with: 7A - Universal / GPC-7, 7N - Universal / N, male, 7NF - Universal / N, female, 7S - Universal / 3.5 mm, male. Opt 10A, High Stability Ovenized Time Base and 1 Hz Resolution.



 

Standard Calibration $800.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU 37347C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Standing Wave Ratio (SWR)
Standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).


Please contact us for your ANRITSU 37347C REPAIR and/or ANRITSU 37347C 20 GHz Lightning Vector Network Analyzer (VNA) CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: