ANRITSU MA2445D CALIBRATION and ANRITSU MA2445D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MA2445D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   ANRITSU MA2445D   Description / Specification:    
ANRITSU MA2445D 50 GHz High Accuracy Diode Sensor

The Anritsu MA2445D 50 GHz High Accuracy Diode Sensor is designed for use with the ML2430, ML2480 and ML2490 series power meters. They are designed for high dynamic range, high accuracy CW and TDMA measurements. With a built-in 3 dB attenuator, the MA2445D minimizes input SWR and is best used where the best measurement accuracy is required over a large dynamic range, as when measuring amplifiers. The MA2445D sensor has a dynamic range of 87 dB compared to the 90 dB dynamic range of MA247xD standard diode sensors. Specifications. Frequency Range: 10 MHz to 50 GHz. Dynamic Range: –67 dBm to +20 dBm. SWR: <1.90; 10 MHz to 50 MHz, <1.17; 50 MHz to 150 MHz, <1.08; 150 MHz to 2 GHz, <1.16; 2 GHz to 12.4 GHz, <1.21; 12.4 GHz to 18 GHz, <1.29; 18 GHz to 32 GHz, <1.44; 32 GHz to 40 GHz, <1.50; 40 GHz to 50 GHz. Rise Time (the time interval necessary for the power sensor to rise from 10% to 90% of the reading when the signal rises instantaneously from zero (no power) to 1 mW (0 dBm) at room temperature): <0.004 ms. Sensor Linearity –67 to +15 dBm: 1.8% <18 GHz, 2.5% <40 GHz, 3.5% <50 GHz. RF Connector Type: V (m). Maximum Input Power: 23 dBm, CW; 30 dBm, 1 µs peak, ±20 Vdc.



 

Standard Calibration $290.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MA2445D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your ANRITSU MA2445D CALIBRATION and/or ANRITSU MA2445D 50 GHz High Accuracy Diode Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: